EasyManuals Logo

EINHELL BG-WW 1140 NN User Manual

EINHELL BG-WW 1140 NN
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
GB
Faults Cause Remedy
Motor fails to start up - No mains voltage
- Pump rotor blocked -thermostat
switched off
- Check voltage
- Dismantle and clean pump
No intake - Intake valve not in water
- Pump chamber without water
connection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery rate - Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance
diminishedby contaminants part
- Check suction height
- Clean strainer
- Immerse intake valve deeper
- Clean pump and replace
wearing
Thermostat switches pump off - Motor overloaded - friction
caused by foreign substances
too high
- Dismantle and clean pump.
Prevent intake of foreign
substances (filter)
12. Troubleshooting guide
Anleitung_BG_WW_1140_NN_SPK1:_ 02.07.2010 10:14 Uhr Seite 13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL BG-WW 1140 NN and is the answer not in the manual?

EINHELL BG-WW 1140 NN Specifications

General IconGeneral
BrandEINHELL
ModelBG-WW 1140 NN
CategoryWater Pump
LanguageEnglish

Related product manuals