GC-DW 900 N
Art.-Nr.: 41.709.64 I.-Nr.: 11025
7
D Originalbetriebsanleitung
Tauchdruckpumpe
GB Original operating instructions
Submersible pressure pump
F Mode d’emploi d’origine
Pompe refoulante submersible
I Istruzioni per l’uso originali
Pompa premente ad immersione
HR/ Originalne upute za uporabu
BIH Potopna tlačna pumpa
RS Originalna uputstva za upotrebu
Potopna pumpa
E Manual de instrucciones original
Bomba sumergible a presión
RO Instrucţiuni de utilizare originale
Pompă de presiune submersibilă
TR Orijinal Kullanma Talimatı
Dalgıç Pompa
Anl_GC_DW_900_N_SPK7.indb 1 24.06.15 13:16
www.sidirika-nikolaidi.gr

Table of Contents

Questions and Answers

  • S
    Sara McbrideAug 13, 2025
    Why does my EINHELL Water Pump switch off after briefly running?
    • L
      Leslie ArellanoAug 13, 2025
      Your EINHELL Water Pump might be switching off shortly after starting due to a couple of reasons: * The motor circuit-breaker might be tripping because of excessive water contamination. If this is the case, unplug the power and clean the equipment and shaft. * Alternatively, the water temperature may be too high, causing the motor circuit-breaker to switch off the equipment. Ensure that the water temperature does not exceed 35 °C.
  • U
    ucampbellAug 17, 2025
    Why EINHELL GC-DW 900 N Water Pump has insufficient pumping rate?
    • C
      curtisadamAug 17, 2025
      An insufficient pumping rate in your EINHELL Water Pump can occur due to: * A clogged intake sieve. Clean the intake sieve. * Reduced performance caused by heavily contaminated and abrasive water impurities. Clean the equipment and replace any worn parts.
  • B
    Brian CarrollAug 20, 2025
    What to do if my EINHELL GC-DW 900 N doesn't start?
    • N
      Nichole MillerAug 20, 2025
      If your EINHELL Water Pump isn't starting, first check the power supply to ensure it's properly connected. If the power supply is fine, then check if the floating switch is triggering; if not, raise the position of the floating switch.
  • W
    William HoodAug 25, 2025
    What to do if my EINHELL GC-DW 900 N Water Pump does not start?
    • V
      Veronica MillsAug 25, 2025
      If your EINHELL Water Pump doesn't start, there are a couple of things you can check: * First, make sure the power supply is properly connected. * Second, check the floating switch. If it's not triggering, raise its position.
  • D
    Denise VargasAug 28, 2025
    What to do if my EINHELL GC-DW 900 N Water Pump does not pump water?
    • K
      Kristina LittleAug 28, 2025
      If your EINHELL Water Pump isn't pumping water, it could be due to a couple of issues: * The intake sieve might be clogged. If so, clean it with a water jet. * The discharge hose could be kinked. Straighten the hose to remove any kinks.
  • W
    William HolmesSep 1, 2025
    What to do if my EINHELL Water Pump does not cut out?
    • L
      lewisdebbieSep 1, 2025
      If your EINHELL Water Pump isn't cutting out, it might be because the floating switch can't sink. Ensure the equipment is correctly placed on the shaft bottom.
  • G
    Gregory NelsonSep 4, 2025
    What to do if my EINHELL GC-DW 900 N Water Pump doesn't pump water?
    • O
      Olivia Smith DVMSep 4, 2025
      If your EINHELL Water Pump isn't pumping water, check if the intake sieve is clogged and clean it with a water jet. Also, inspect the discharge hose for any kinks and unkink it.
  • K
    Kimberly GreeneSep 9, 2025
    What to do if EINHELL GC-DW 900 N Water Pump does not cut out?
    • E
      Erin HumphreySep 9, 2025
      If your EINHELL Water Pump does not cut out, it might be because the floating switch cannot sink. Try lowering the position of the floating switch.

Summary

Safety Regulations

General Safety Precautions

Essential safety measures to prevent injuries and damage during equipment use.

Layout and Items Supplied

Layout (Fig. 1)

Details of the pump's physical components and their identification numbers.

Items Supplied

Information on checking the contents of the package against the delivery scope.

Proper Use

Technical Data

Before Starting the Equipment

Installation

Instructions for setting up the pump, including connecting hoses and securing the appliance.

Mains Connection

Operation

Setting the On;Off Switching Point

Adjusting the floating switch to control the pump's automatic on/off operation.

Replacing the Power Cable

Cleaning, Maintenance and Ordering of Spare Parts

Cleaning and Maintenance Procedures

Instructions for cleaning the pump and performing routine maintenance tasks.

Cleaning the Paddle Wheel

Maintenance

Ordering Replacement Parts

Disposal and Recycling

Storage

Troubleshooting Guide

The equipment does not start

Troubleshooting steps for when the pump fails to initiate operation.

The equipment does not pump

Solutions for common causes when the pump is not delivering water.

The equipment does not cut out

Diagnosing and resolving issues where the pump fails to stop automatically.

Insufficient pumping rate

Addressing problems related to reduced water flow or pumping performance.

The equipment switches off after briefly running

Identifying reasons for the pump shutting down prematurely after starting.

Service Information

Wear Parts

List of components subject to normal wear, such as the impeller.

Consumables

Parts that may be required for use, though not necessarily included in the scope of delivery.

Missing Parts

Information on how to report and order parts that were not delivered with the equipment.

Warranty Certificate

Warranty Terms and Conditions

Details regarding warranty coverage, exclusions, and claim procedures.

Declaration of Conformity

EINHELL GC-DW 900 N Specifications

General IconGeneral
Maximum delivery height32 m
Depth of immersion (max)7 m
Product colorRed
Housing materialStainless steel
AC input voltage230 V
AC input frequency50 Hz
Weight and Dimensions IconWeight and Dimensions
Weight8900 g