11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected
- Floating switch does trigger
- Check power supply
- Raise position of oating switch
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Floating switch cannot sink - Place equipment correctly on shaft
bottom
Insu cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o after brie y
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GC_DW_900_N_SPK7.indb 18 24.06.15 13:16
www.sidirika-nikolaidi.gr

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GC-DW 900 N and is the answer not in the manual?

EINHELL GC-DW 900 N Specifications

General IconGeneral
Maximum delivery height32 m
Depth of immersion (max)7 m
Product colorRed
Housing materialStainless steel
AC input voltage230 V
AC input frequency50 Hz
Weight and Dimensions IconWeight and Dimensions
Weight8900 g