EasyManua.ls Logo

EINHELL GC-RT 7530 - Troubleshooting; Motor Start Issues; Motor Performance Problems

EINHELL GC-RT 7530
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
- 21 -
11. Troubleshooting guide
Fault Possible causes Remedy
Motor does not start - No power at the plug
- Cable defective
- Switch/plug block defective
- Motor terminals or capacitor
disconnected
- excessive working depth
- Check the power cable and fuse
- Check
- By customer service workshop
- By customer service workshop
- Reduce working depth
Motor performance
drops
- Soil too hard
- Blades badly worn
- Correct working depth
- Replace hoe blades
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period.
Anl_GC_RT_7530_SPK1.indb 21Anl_GC_RT_7530_SPK1.indb 21 13.11.14 17:1113.11.14 17:11