EasyManua.ls Logo

EINHELL GE-CM 33 Li Kit - Charger Indicator

EINHELL GE-CM 33 Li Kit
174 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
- 28 -
11. Charger indicator
Indicator status Explanations and actions
Green is ß ashing Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Red in on Charging
The charger is charging the battery pack.
Green is on The battery is charged and ready for use.
(Charging time for 1.5 Ah battery: approx. 2 hours)
(Charging time for 2.0 Ah battery: approx. 2½ hours)
(Charging time for 3.0 Ah battery: approx. 4 hours)
(Charging time for 4.0 Ah battery: approx. 5 hours)
(Charging time for 5.2 Ah battery: approx. 6½ hours)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Red is ß ashing Fault
Charging is no longer possible. The battery pack or charger is defec-
tive.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Red and green are ß ashing
alternately
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .
Should this fault still occur afterwards, the battery has undergone ex-
haustive discharge and must never be charged or used again. Take the
battery pack out of the charger.
* For our latest prices and information please go to www.isc-gmbh.info
Anl_GE_CM_33_Li_Kit_Solo_SPK7.indb 28 10.10.2016 16:14:30