10. Troubleshooting
Fault Mögliche Ursache Behebung
Engine does not
start
Automatic oil cut-out has not respon-
ded
Spark plug fouled
No fuel
Check oil level, top up engine oil
Clean or replace spark plug (electro-
de spacing 0.6 mm)
Refuel / have the petrol cock checked
Generator has too
little or no
voltage
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air lter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the lter
The battery does
not charge up
Poor contact to the battery
Battery defective
Defective fuse (Fig. 16a/16b)
Clean the contacts
Have the battery checked by an ex-
pert and replace it if necessary
Check the function of the equipment
using a di erent battery; replace the
fuse
Starter does not
turn
Battery discharged
Battery not connected
Charge the battery
Connect the battery
Anl_TC-PG_55_E5_SPK9.indb 26Anl_TC-PG_55_E5_SPK9.indb 26 17.06.2019 07:18:0617.06.2019 07:18:06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL TC-PG 55/E5 and is the answer not in the manual?

EINHELL TC-PG 55/E5 Specifications

General IconGeneral
BrandEINHELL
ModelTC-PG 55/E5
CategoryPortable Generator
LanguageEnglish

Related product manuals