10. Charger indicator
Indicator status
Explanations and actions
Red LED Green LED
O Flashing Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
On O Charging
The charger is charging the battery pack in quick charge mode.
O On The battery is charged and ready for use.
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Flashing O Adapted charging
The charger is in gentle charging mode.
For safety reasons the charging is performed less quickly and takes
more time. The reasons can be:
- The rechargeable battery has not been used for a very long time.
- The battery pack temperature is outside the ideal range (between 10°
C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Flashing Flashing Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
On On Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .
Anl_TE_CI_12_Li_SPK9.indb 22 06.03.2018 11:13:38