EasyManua.ls Logo

EKO MP-11 - Page 36

EKO MP-11
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EKO INSTRUMENTS CO., LTD. I-V Curve Checker MP-11 Instruction Manual Ver.7
Pg. 35
4)
Unexpected shape with large missing part
Many of modules with low irradiation or large
shadow
5)
Unexpected shape with small missing part around Pm
A few modules (or clusters) with low irradiation or
small shadow
Uneven pollution of module surface
A few hotspots on module
Variation of module performance, such as Isc,
mismatch in a couple of modules in a string
6)
Unexpected shape with missing between Voc and
around Pm
One module or a few modules with low irradiation
7)
Unexpected shape with moderate slope from Voc
Large series resistance of PV cables or high
contact resistance of connectors
Degradation of interconnect in module
8)
Unexpected shape with steep slope from Isc
Small parallel resistance of module.
Damaged bypass diode in connection box of
module

Related product manuals