Table 11-2 Software Specifications - Continued
Items
Details
Software
Functions
Data Saving
Save data measurement date setting
Automatic exclusion of data with insufficient irradiance
Filtering by PV module/array name
Measurement data list:
List data specified by measurement date with main parameters.
Save data: Data number, date, time, PV module/array name, PV
module/array area, irradiance, VocIscPmax, FF, η, Vpm, Ipm
Data sorting function in each display; ascending/descending order switch
Create Individual Conversion File CSV file):
Save the data selected from the data list into CSV format data
File ID setting (8 alphanumerical characters): Added at the head of the
CSV file name for file identification.
Characteristics Value Conversion: Generate file with parameter list for the
selected data.
Prepare Report Function: Report file created for the data selected.
Report file in Microsoft Excel format.
Irradiance Graph
Display
Save data measurement date setting
Automatic exclusion of data with insufficient irradiance
Filtering by PV module/array name
Display following graphs for the data selected from the data list
Irradiance Voc, Irradiance-Isc, Irradiance-Pmax, Irradiance-FF
Other Functions
Main Unit time setting function
Reading and displaying firmware version from Main Unit and Sensor Unit.
Parameter Setting: Upload & download
PV module/array area, short circuit current temperature coefficient, open
circuit voltage temperature coefficient, series resistance, curve correction
factor, PV module quantity, comment (installation site name, PV
module/array name, PV module/array type)
Reference Irradiance Setting: Irradiance measurement,
pyranometer/reference cell sensitivity setting
Irradiance threshold, averaging measurement frequency
Temperature Setting: PV module/array temperature and ambient
temperature measurements, averaging measurement frequency setting
Parameter file upload, saving
Connection port selection
Data Saving Folder Setting: Specify a folder for saving measurement data.
Common folder for display and save data file
Record File Data Output Folder Setting: Assign a folder for saving record
file.
Simple Report Output: Creating report of specified measurement data
results in Microsoft Excel format. Report format can be modified by
Microsoft Excel
*) ”Excel“ is a brand name by Microsoft