EasyManua.ls Logo

elco LOGON SOL plus - Safety Instructions; Product Description and Technical Data; Accessories and Package Contents

elco LOGON SOL plus
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Table of Contents
Safety instructions
Product description, specifications
Accessories, package contents
Safety instructions
All electrical work shall be carried out
exclusively by licensed electricians.
When installing or repairing electrical
equipment, always be sure that it is
completely isolated from the supply. Do
not work on live parts.
Install the controller in a dry room and
at a location where it is not exposed to
temperatures > 50°C.
Temperatures can reach as high as
90°C in the connected storage tanks.
As a result, boiling protection must be
provided for domestic hot water storage
tanks (Heizungsanlagenverordnung
Section 8, Clause 2 (heating systems
directive).
The supplied wall-mount enclosure
shall only be used for a stationary in-
stallation.
Product description
Solar controller installed in wall-
mount enclosure to control solar
heating systems for domestic hot
water heating and backup heating.
Ausstattung des Reglers:
Controller features:
Installation
The assembly and initial start-up
shall be done exclusively by author-
ized professionals who assume
responsibility for proper installation
and start-up.
Following initial startup, the opera-
tor will be given instructions regard-
ing user-related features of the con-
troller.
This training is the responsibility of
the authorized professional in-
staller.
Details regarding warranty condi-
tions
The warranty does not cover dama-
ge resulting from any of the follo-
wing:
improper use
improper installation or start-up by the
purchaser or third parties, including
the use of third-party components
Adhering to the following will ensu-
re that the warranty applies:
operating the equipment as it was
designed to be used.
Technical data
supply voltage: 230 V (AC) 50...60
Hz, power consumption 3 VA
enclosure type 2 according to EN
60730, enclosure type IP 40 per DIN
40050
electrical connection via a RAST 5
connector inside the wall-mount en-
closure (controller can be plugged in)
10 sensor inputs for NTC temperature
sensors
(range: -20 to +149 °C) and solar
sensor
1 input for measuring volume flow
6 relay outputs: 3 standard (2A) and 3
solid-state relays (1 A) for variable
speed control
1 relay output (low voltage) for ba-
ckup heating enable
auxiliary module for e-Bus connection
or two additional relay outputs
Package contents
wall-mount enclosure
LOGON SOL plus controller
collector sensor (NTC red cable)
for temperatures up to 250°C
temperature measuring range
-20°C to 150°C
rated temperature range
-20°C to 250°C
two sensors (NTC white cable)
for installation as storage tank and
return-line sensor
temperature range
-20°C to 150°C
rated temperature range
-20°C to 250°C
thermowell – 100 mm / ½ "
for installation in the collector
adjustable thermowell, maximum
length 350 mm / ½ " for installation of
the return-line sensor
thermowell – 150 mm / ½"
for installation of the storage tank
sensor
large, clearly arranged LCD screen
displays all key system temperatu-
res at a glance
controller can be plugged into so-
cket in wall-mount enclosure
seven timer channels for backup
heating using a conventional boiler
or auxiliary heater and for special
functions
differential temperature control for
solar systems with up to two collec-
tor panels and three storage tanks
twelve predefined system circuits to
configure the solar system and faci-
litate start-up
speed control for up to three circula-
ting pumps
solar system heat gain calculation
priority selection for multiple storage
tank systems
backup heating via heating circuit
return flow boosting
bypass circuit for large collector
surfaces and long piping runs
external heat exchanger for large
systems with several buffer storage
tanks
low flow concept ideal for stratified
heat transfer technology
freeze protection and overheating
protection features for collector and
storage tank
hot water destratification and Legio-
nella protection functions
thermostat, temperature compari-
son and timer functions
connection port for data logger
oscillation heating to utilize residual
heat