9-6
HOW TO USE YOUR MOTORHOME’S EQUIPMENT
Electrical operation
To start the refrigerator press the mode button
(1) for 2 seconds. The LED of the previously
selected operating mode will illuminate.
Change the operating mode by pressing the
mode button (1) again, and the appropriate
indicator
LED (6) will illuminate.
Gas operation (LPG)
Prior to starting the refrigerator in gas mode:
Open the gas cylinder valve
Open the isolation valve inside the vehicle
for gas supply to the refrigerator
Press the mode button (1) several times until the
indicator LED (6) shows the gas flame. The
ignition process is then activated automatically.
Note that the ignition system will make 2
attempts with 25 seconds interval to light. If
repeated attempts fail to start the operation, a
fault is indicated (please refer to troubleshooting
section).
Temperature setting
Select the desired cooling department
temperature by pressing button 2, and the LED
display (7) is illuminated. The scale starts with
MIN position at the bottom LED position (small
crystal = highest temperature) and climbs up to
MAX position at the upper LED position (large
crystal = lowest temperature). Note the
temperature levels do not relate to absolute
temperature values.
The refrigerator’s performance is influenced by
ambient temperatures. Please select the medium
temperature setting for ambient temperatures
between +15
o
C and + 25
o
C.
For temperatures below +10
o
C winter covers
should be fitted to the outside vents.
1 Power on switch / Energy selector switch
(MODE).
2 Temperature selection.
3 Door opening (only when equipped with
electrical door lock).
4 Indicator LED failure.
5 Indicator LED door lock (optional).
6 Indicator-LED / operating mode display.
7 Temperature level display.
Operating controls
Maintenance
In order to comply with applicable gas standards, the gas unit and ventilation ducts must be checked by an
authorized technical person at regular intervals, and a test certificate issued. It is the user’s responsibility to
arrange this test.
The gas burner must be inspected and cleaned as necessary, at least once a year.
Work on gas and electrical equipment shall be carried out by qualified personnel only.
This work can be carried out by the Explorer Group Service Centre at the annual habitation service, or
after an extended shutdown period.