Power Key (2) Press to turn the dehumidifier on and off.
Humidity Settings Keys (3) humidity level can be set within a range of 40% RH
(Relative Humidity) to 80% RH in 5% increments. Ideal setting is
50-55%. For drier air/ laundry mode press the key and set to a lower
percent value (e.g. 40-45%).
For allowing more moisture in the air, press the humidity control key and
set to a higher percent value(e.g. 60-65%).
The humidity control key will cycle from 40-80%RH and back to 40%RH
Continuous/ Laundry Mode for the dehumidifier to operate continuously for
maximum water extraction until the tank is full set the humidity level to 40%RH.
40% is very dry and the unit will work until water tank is full as 40%RH is hardly
achievable in UK domestic environment.
Timer (4) settings (1-24 hrs, start/ stopping timer). In power on mode the
set number will represent the number of hours the unit will stop. This will remain
unaffected if unit goes in defrost mode or tank is emptied than reinserted. In
standby mode the set number represent period in hours after the unit will start. To
cancel start / stop mode set the timer to 00.
Other features and Indicators
Tank Full Light
Red light will be on and the unit will beep when the tank is ready to be emptied, or
when the tank is removed or not replaced in the proper position. The water level
control switch shuts off the dehumidifier when the tank is full, or when the tank is
removed or not replaced in the proper position. Empty to resume operation.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the
unit will go in defrost mode
When the unit is running in a room with temperature between 5C and 12C, it
enter the defrost mode about once every 30 minutes.
When the unit is running in a room with temperature between 12C and 20C, it
enter the defrost mode about once every 45 minutes.
Normal operation will resume after defrost mode.
Humidistat control and fan/ compressor operation
When the selected humidity is lower by 2% than the user selected humidistat
setting; the dehumidifiers compressor will be shut off automatically but the fan
will still move for few more minutes to ensure air is not stale in the room. The unit
will use only a minimal amount of energy in fan mode.
When the humidity is going back to being equal or higher than user selected
humidity the compressor will restart once the 3 minutes delay compressor
protection expires.
5
All manuals and user guides at all-guides.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ElectrIQ CDW12L and is the answer not in the manual?

ElectrIQ CDW12L Specifications

General IconGeneral
BrandElectrIQ
ModelCDW12L
CategoryDehumidifier
LanguageEnglish

Related product manuals