15
RESTORING FACTORY SETTINGS
To restore the Super Switcher to factory default settings:
1. Unplug the Super Switcher from power.
2. Press and hold the CTRL 1 & CTRL 2 footswitches while plugging
power back in to the Super Switcher.
3. The character display will read
E-H
.
4. Release the two Control footswitches.
5. Press the BOOST footswitch and the character display will read
rSt
.
6. Press the BANK DOWN footswitch. The Super Switcher will restore to
factory settings and the character display will read
dUN
.
7. Unplug power from the Super Switcher and reapply power to
perform a power cycle.
8. The Super Switcher factory settings are now restored.