EasyManua.ls Logo

Electrolux 134709300 - Installation Requirements; Electrical System Specifications

Electrolux 134709300
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Installation Requirements
IMPORTANT
This dryer is internally grounded to neutral unless it
wasmanufacturedforsaleinCanada.Grounding
throughtheneutrallinkisprohibitedfor:(1)new
branchcircuitinstallations,(2)mobilehomes,(3)
recreationalvehicles,and(4)areaswherelocal
codes do not permit grounding through the neutral.
NOTE
Dryers manufactured for sale in Canada have
factory-installed, 4-wire power supply cord
(NEMA14-30R).
Electrical system requirements
Electrical requirements for electric dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers. Use separately fused circuits for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.
POWERSUPPLY-3-wireor4-wire,240volt,
singlephase,60Hz,AlternatingCurrent.
3-WIREPOWERSUPPLYCORDKIT(notsupplied)
OUTLETRECEPTACLE-NEMA10-30RorNEMA
14-30R receptacle to be located so the power
supply cord is accessible when the dryer is in the
installed position.
GROUNDINGCONNECTION-See“Grounding
requirements” in Electrical Installation section.
ThedryerMUSTemploya3-conductorpower
supplycordNEMA10-30typeSRDTratedat
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends
or closed loop connectors and marked for use
4-WIREPOWERSUPPLYCORDKIT(notsupplied)
ThedryerMUSTemploya4-conductorpower
supplycordNEMA14-30typeSRDTorST(as
required)ratedat240voltACminimum,30amp,
with 4 open end spade lug connectors with
upturned ends or closed loop connectors and
marked for use with clothes dryers. For 4-wire
cord connection instructions see ELECTRICAL
CONNECTIONSFORA4-WIRESYSTEM.
Electrical requirements for gas dryer:
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.
POWERSUPPLY-2-wire,withground,120volt,
singlephase,60Hz,AlternatingCurrent.
POWERSUPPLYCORD-Thedryerisequipped
with a 120 volt 3-wire power cord.
GROUNDINGCONNECTION-See“Grounding
requirements” in Electrical Installation section.
Grounding type
wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
3-wire receptacle
(NEMAtype10-30R)
4-wire receptacle
(NEMAtype14-30R)
NOTE
Becauseofpotentiallyinconsistentvoltagecapabilities,theuseofthisdryerwithpowercreated
by gas powered generators, solar powered generators, wind powered generators or any other
generator other than the local utility company is not recommended.
with clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS
FORA3-WIRESYSTEM.