5. Adjust the "LOW" Setting of the Dual Burner
(see Figure 8) on the Surface Burner Valve (Figure
10):
Note: On the dual valve the low setting of each portion
(rear portion of bridge burner and the center portion of
bridgeburner)shouldbeadjustedindividually.
a. Push in and turn control to LITE until the rear portion
of the bridge burner ignites only.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. The inner portion of the dual burner flame size can be
increased or decreased by turning screw A (see Figure
10). Use screw Btoadjusttheamesizeoftheouter
portion of the dual burner. Turn counterclockwise
the screw to increase flame size. Turn clockwise the
screwtodecreaseamesize.Adjustameuntilyou
can quickly turn knob from LITE to LOWEST POSITION
without extinguishing the flame. Flame should be as
small as possible without going out.
Note:Airmixtureadjustmentisnotrequiredonsurface
burners.
Figure 10
Figure 9
4. Adjust the "LOW" Setting of Regular Burner (see
figure 8) on the Surface Burner Valves (Figure 9):
a. Push in and turn control to LITE until burner ignites.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob and
decorative ring.
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame
size can be increased or decreased by turning the
screw. Turn counterclockwise to increase flame size.
Turnclockwisetodecreaseamesize.Adjustame
until you can quickly turn knob from LITE to LOWEST
POSITION without extinguishing the flame. Flame
should be as small as possible without going out.
Note:Airmixtureadjustmentisnotrequiredonsurface
burners.