- 12 -
599 529 016DGS-TDS-N 11.08 U.H. © Electrolux EN
Error description Fault cause Testing Troubleshooting
Phase, connection link missing Test voltage, connection Insert new fuse
Activate fuse
Insert connection stud
Module left defective Fusing/conductor rail of the filter left defective Replace performance part and filter
Control unit defective Replace control unit
Replace bus line
Phase, connection stud missing Test the voltage at the house installation Insert new fuse
Activate fuse
Module right defective Fusing/conductor rail of the filter right defective Replace performance part and filter
Connection line between the modules Replace line
Control unit defective Replace control unit
Appliance cannot be
switched on
Zone left cannot be
activated
Special error possibilities with regard to "Maxima Extension"