- 11 -
599 529 016DGS-TDS-N 11.08 U.H. © Electrolux EN
4. Error analysis
Error code timer
Coil left
Module left
Coil middle
Module middle
Coil right
Module right
Error indications/
Error analysis Error Cause Error Remedy
E0 Incorrect or incomplete configuration Install new filter
E1 Internal electronic error Install new filter
E2 Pot detection Install new filter
E3 Excess voltage --> 400V Check connection
E4
Sensor not plugged or defect. Connections not
reserved
Install new coil
E5
Zero crossing of the mains voltage
incompatible
Check mains
E6
Defect in the communication to the power
board
Install new filter
E7 Sensor on heat sink defect
Install new power
electronics
E8
Communication between induction and
interface in failure
Install new input
electronics
E9 Configuration data for interface incompatible Install new filter
No pot detection on L.H.
hot plate
No pot detection on
central hot plate
Phase or neutral for L.H. module not
connected or available
Check connection
No pot detection on R.H.
hot plate
Phase or neutral for module not connected or
available
Check connection
No indication on R.H. hot
plate
Connecting line between modules missing or
defect Replace line
Indication above L.H. hot
plate is lit L.H. module not programmed Install new filter
Central indication off and
R.H. indication "E" (E4)
Both modules not programmed Install new filters
R.H. indication "E" (E4)
Right module not programmed, sensor for the
right cooking plate defective
Install new filter.
Replace coil