Troubleshooting
TROUBLESHOOTING GUIDE
!
DD
DD
D
ANGERANGER
ANGERANGER
ANGER
ELECTROCUTION HAZARD
NEVER attempt to repair or perform maintenance on the unit until the main electrical
power has been disconnected.
Troubleshooting – What to check when problems occur
Problem Possible Cause Remedy
Unit not cold enough.
Check temperatures (see
introduction for specific
temperatures).
Control set too warm.
Light staying on.
Airflow to front grille blocked.
Dirty condenser coils.
Door gasket not sealing properly.
Turn control knob CLOCKWISE to set
temperature colder. Allow 24 hours for
temperature to stabilize.
Check that light switch bracket contacts switch
plunger.
Airflow must not be obstructed to front grille. See
Installation.
Clean condenser. See Maintenance.
Adjust door gasket.
Unit too cold.
Check temperatures (see
introduction for specific
temperatures).
Control set too cold.
Turn control knob COUNTER-CLOCKWISE to
set temperature warmer. Allow 24 hours for
temperature to stabilize.
No interior light.
Loose or burned out bulb.
Tighten or replace bulb. See Bulb Replacement.
Light won’t go out when door is
closed.
Light on/off switch is turned to ON.
Turn switch to OFF. See Light Switch and Bulb.

Other manuals for Electrolux E24WC48EPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electrolux E24WC48EPS and is the answer not in the manual?

Electrolux E24WC48EPS Specifications

General IconGeneral
BrandElectrolux
ModelE24WC48EPS
CategoryWine Cooler
LanguageEnglish

Related product manuals