IInnssttaallllaattiioonn IInnffoorrmmaattiioonn
2-10
FFiigguurree 22--99..
FFiigguurree 22--88..
EElleeccttrriiccaall CCoonnnneeccttiioonn ((nnoonn--CCaannaaddaa)) -- 33 WWiirree CCoorrdd
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block
access cover in the lower corner on the back
of the dryer.
3. Install a UL-approved strain relief according
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 10-30 type SRDT,
through the strain relief.
5. Attach the power cord neutral (center wire)
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely. (See Figure 2-8 & 2-9)
6. Attach the remaining two power cord outer
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
7. Follow manufacturer’s guidelines for firmly
securing the strain relief and power cord.
8. Reinstall the terminal block cover.
EELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD
FFAAIILLUURREE TTOO DDIISSCCOONNNNEECCTT PPOOWWEERR SSOOUURRCCEE
BBEEFFOORREE SSEERRVVIICCIINNGG CCOOUULLDD RREESSUULLTT IINN
PPEERRSSOONNAALL IINNJJUURRYY OORR EEVVEENN DDEEAATTHH..
EELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD
DDOO NNOOTT MMAAKKEE AA SSHHAARRPP BBEENNDD OORR CCRRIIMMPP
WWIIRRIINNGG// CCOONNDDUUCCTTOORR AATT CCOONNNNEECCTTIIOONNSS..
IIff mmoovviinngg ddrryyeerr ffrroomm aa 44--wwiirree ssyysstteemm aanndd
iinnssttaalllliinngg iitt iinn aa 33--wwiirree ssyysstteemm,, mmoovvee tthhee iinntteerrnnaall
ggrroouunndd ffrroomm tthhee cceenntteerr tteerrmmiinnaall bbaacckk ttoo tthhee
GGRREEEENN ssccrreeww nneexxtt ttoo tthhee tteerrmmiinnaall bblloocckk..