23
L.2 Alarms
Anomaly Type of anomaly Possible causes Actions
A1 NO WATER The tap is close.
The water inlet filter is clogged.
Too low pressure in hydraulic circuit.
Overflow not inserted (only for applian-
ces without drain pump).
Open the tap.
Clean the water inlet filter.
Check the minimum mains pressure.
Insert properly the overflow.
B1 INEFFICIENT
DRAINAGE
Overflow not removed.
The waste outlet pipe and/or the overflow
aperture obstructed.
Remove the overflow.
Remove any obstruction from the waste
outlet pipe and/or the overflow aperture.
B2 TANK WATER LEVEL
TOO HIGH
The waste outlet pipe and/or the overflow
aperture obstructed.
Remove any obstruction from the waste
outlet pipe and/or the overflow aperture.
C1 – C8 CALL THE SERVICE CENTRE
E1 – E8 The appliance continues to operate, but
appropriate checks by a technician are
recommended.
CALL THE SERVICE CENTRE
F21 – F22
1
Resin regeneration cycles are not per-
formed. The appliance continues to
operate without water softener.
CALL THE SERVICE CENTRE
1. Only for appliances with incorporated continuous water softener.