Water connection
The water inlet temperature on the cold water connection should be
max. 25°C.
If plastic pipe systems are used as installation material, the pipe
manufacturer must expressly and unreservedly confirm the
applicability and quality of his pipes for this application.
The ELECTROLUX IH electronic can be operated with all pressure fittings
suitable for instantaneous water heater.
Insert connector with shutoff spindle (1) in
cold water connection and double- nipple
(2) in hot water outlet using hemp packing.
The shutoff spindle must point downwards
and the screw slot aligned in the flow
direction of the water. The shutoff unit
must not be used for throttling.