ces. Rating of the in-line fuses (one per
phase): 10 A at 230 V.
Installation must be done in con-
formance with the applicable co-
des, the requirements of the
standard NF.C.15100 and the re-
quirements of the electrical energy
supplier.
Use a power supply socket that has an
earth connection and this must be con-
nected in conformance with the standard
15100 and the requirements of the suppli-
er of electrical energy. this power supply
socket must be accessible. If the mains
supply cable is damaged, it must be re-
placed by a certified supply cable. This
must be done only by a skilled person,
the seller or the manufacturer. The appli-
ance must not be connected via an ex-
tension cable, a multiple socket or a multi-
ple connector (risk of fire). Make sure the
earthing connection complies with the
regulations in force.
We will accept no responsibility in the
event of accidents or incidents caused by
non-existent or defective electrical earth-
ing connections.
7.3 Door reversibility
The door of the appliance opens to the
right. To open the door to the left, do
these steps before you install the appli-
ance.
Loosen and remove the upper pin.
Remove the upper door.
Remove the spacer.
Loosen the middle hinge.
Remove the lower door.
Loosen and remove the lower pin.
On the opposite side:
Tighten the lower pin.
Install the lower door.
Tighten the middle hinge.
Install the spacer.
Install the upper door.
Tighten the upper pin.