LOCATION OF APPLIANCE
The appliance may be located in a kitchen, a kitchen/diner or bedsitting room, but not located in a bathroom,
shower room or garage.
It is essential that there is a minimum clearance of 3mm between the top surface of the appliance and
the inside top of the cabinet. The unit must be fitted into a cabinet conforming to Fig. 1. The following
internal dimensions are particularly important.
Height 874............Minimum 879..........Maximum
Width 560............Minimum 570..........Maximum
Solid Pipe Depth 560........... Minimum N/A.........Maximum
Flexible Pipe Depth 575............Minimum N/A.........Maximum
NOTE: Where a cupboard door with a handle is situated above the appliance, we recommend a minimum
clearance gap of 5mm between fascia top trim and door.
L.P.G. cookers MUST NOT be installed below ground level, i.e. in a basement.
38
2000 recommended
560 min
879 max
874 min
Fig.1