1.Regulation
The temperature is regulated via an air sensor located in the front of the cold
module.
The evaporator sensor checks when the defrosting is executed.
The cabinet is normally defrosted 1 time / 24 h.
When the door is opened the fan stops immediately.
When starting the cabinet when the temperature inside is warmer than 0°C, the
defrosting starts 8 minutes after start.
2. The ERF2000 panel
A) ON / OFF button - lights when running
B) Freezer thermometer
C) Temperature selector / Thermostat
D) Temperature selector / Thermostat
E) Freezing button, freezing lamp - lights when freezing
F) Warning lamp - flashes on alarm, reset button for alarm