Technical Support - A.D.L. 13/70 599 74 23-12 Rev.00
4.2 Reading the alarms
The last three alarms stored in the FLASH memory of the circuit board can be displayed:
Enter the diagnostic mode.
Irrespective of the type of circuit board and configuration, turn the programme
selector knob clockwise to the eleventh position and this will display the last
alarm.
To display previous alarms, press the button to the left of the START/PAUSE
button in sequence (as shown in the figure)
To return to the last alarm, press the START/PAUSE button.