Technical Support - A.D.L. 36/70 599 74 23-12 Rev.00
Drain the water from the tub.
Are the pressure switch tube and
pressure chamber unobstructed?
(disconnect the tube and blow into it to
make sure the system is unobstructed)
–(see Fig.2 and 8)-
E35
E35: Water level too high
E35
The main circuit board measures a water level, using the electronic pressure switch, of more
than 300 mm for longer than 15 secs.
Clean/change the tube and/or the
pressure chamber and repeat the
diagnostic cycle completely to check for
any further alarms.
Replace
the water fill
solenoid valve
and repeat the
diagnostic cycle
to check for any
Run the
diagnostic cycle
at phase 8.
Once the door
has locked, does
the appliance
start to fill with
water?
Change the
analogue
pressure switch
and repeat the
diagnostic cycle
to check for any
further alarms.
Is the wiring
between the main
circuit board and
the analogue
pressure switch
connected
correctly on both
sides?
Replace the main
circuit board and
repeat the
diagnostic cycle
to check for any
further alarms.
Does the
appliance
continue to fill
with water even
when it is switched
off?
Reconnect
and/or replace
the wiring and
repeat the
diagnostic cycle
to check for any
further
alarms.
Y
E
S
NO
Y
E
S
Y
E
N
N
N
Y
E
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see
a
e 6
!
Fig. 2
Fig. 8