EasyManua.ls Logo

Electrolux EWM09312 - E83 Programme Selector Code Error; E86 Programme Selector Configuration Error; E87 Display Board Microprocessor Faulty

Electrolux EWM09312
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support - A.D.L. 58/70 599 74 23-12 Rev.00
E83
E83: Error reading the programme selector code
E83
Selector position code not envisaged by the configuration data or configuration error
E86 E86: Programme selector configuration error E86
E87 E87: Display board microprocessor faulty E87
Turn the appliance on, turn
the programme selector to
every setting: wait at least
10 seconds on each of the
settings before moving on to
the next one. Is alarm E83
shown again?
Replace the display board
and repeat the diagnostic
cycle to check for any
further alarms.
Repeat the diagnostic
cycle to check for any
further alarms.
N
O
YES
Replace the display board and run the diagnostic cycle to check for any further alarms.
Check for any friction
between the control panel
and the knob.
Is it difficult to turn the knob?
N
O
YES
Repair the coupling between
the control panel/selector
knob.
Repeat the diagnostic cycle to
check for any further alarms.
If there are burns on the circuit board,
see
p
a
g
e 6
8
!
If there are burns on the circuit board,
see
p
a
g
e 6
8
!
Replace the display board and run the diagnostic cycle to check for any further alarms.
If there are burns on the circuit board,
see
p
a
g
e 6
8
!

Related product manuals