Technical Support - A.D.L. 64/70 599 74 23-12 Rev.00
EH3
EH3: Supply voltage too low
EH3
Supply voltage value higher than the one configured
Is the supply line disturbed or the mains voltage
out of range?
Replace the main circuit board and repeat the
diagnostic cycle to check for any further
alarms.
Have the electrical system of the home
checked / repaired by the proper Body.
Important
The appliance remains in alarm status until the mains voltage returns to the correct values
or the appliance is switched off (programme selector set to “0”). Only the family of the
alarm is displayed and the diagnostics mode cannot be accessed. The complete alarm can
only be read when the situation has normalised.
N
O
Y
E
S
If there are burns on the circuit board,
see
p
a
g
e 6
8
!
Check that all the connectors are correctly inserted
!
! !