6/38
ERROR CODES
DESIGNATION
Err 1
Bottom probe
Err 2
Top probe
Err 3
Overheating HV transformer
Err 4
Front magnetron circuit problem
Err 5
Rear magnetron
circuit
problem
Err 6
Both magnetrons circuit problem
Error codes
HSPP tech GB 03 09
How to enter the Program mode
Unplug the machine. Plug the machine and simultaneously press buttons 2 and 3 to enter the program mode (PRO on the display).
See the program mode diagram for the details.
List of settings :
Temp: temperature in C° or F°.
trt : temperature of the upper heating plate
trb : temperature of the bottom plate
tCYx: times corresponding to cycle x (1 2 3/4 S)
tt : total time of the cycle
tw: time of micro wave during the cycle
Action on buttons :
A : enter in the setting
B : decrease the value of the setting
C : increase the value of the setting
D : skip to the following parameter