EM303B General Purpose Inverter
73
3: IS* PID output
4: IF* PID output
5: Auxiliary frequency* PID output
F9-09
Frequency of Zero Speed
Detection
0.0050.00/0.050.0
Hz
0.00
297
No.
Function
Range
Unit
Default
Type
S/N
F9-10
Zero Speed Detection
Output Delay
0.00600.00
S
1.00
298
F9-11
Frequency Reach Range
FAR
0.0050.00/0.050.0
Hz
2.50
299
F9-12
FDT1 Increasing Threshold
0.00Fmax /0.0Fmax
Hz
30.00
300
F9-13
FDT1 Decreasing
Threshold
0.00Fmax /0.0Fmax
Hz
30.00
301
F9-14
FDT2 Increasing Threshold
0.00Fmax /0.0Fmax
Hz
30.00
302
F9-15
FDT2 Decreasing
Threshold
0.00Fmax /0.0Fmax
Hz
30.00
303
F9-16
Cut-off Frequency of
Oscillation Suppression
20~400
%
90
304
F9-17
Non-Stop Control Options
at Instantaneous Power
Failure
0: Disabled
1: Enabled
0
305
F9-18
Speed Search Current
0.301.50
0.60
306
F9-19
Speed Search Coefficient
1.001.30
1.05
307
F9-20
Control Voltage of
Non-Stop at Instantaneous
Power Failure
0~800
V
537
308
F9-21
Proportion Gain of
Non-Stop at Instantaneous
Power Failure
0.00~300.00
0.50
309
F9-22
Integral Time of Non-Stop
at Instantaneous Power
Failure
0.00~600.00
S
1.50
310
F9-23
Base Time ofNon-Stop at
Instantaneous Power
Failure
0.00~600.00
S
2.00
311
F9-24
Start Delay Time After
Power-on
0.0010.00 (The time for inverter to wait
for the initial operation after power-on)
S
1.00
312
F9-25
Terminal Operation
Command Control
0: Terminal shall be off first, and then on.
1: Terminal shall not be off, inverter will
run directly.
1
313
F9-26
Voltage Resume Time of
Speed Search
0.005.00
S
0.30
314
F9-27
Oscillation Suppression
020000
300
315