The appliance must be connected with only one phase from main power supply of the indicated voltage and frequency,
shown on the plate with the technical characteristics of the ventilator. The electrical installation must have a phase
switch with at least 3 mm distance between contacts.
CONNECTING TO POWER SUPPLY
Place the ventilator AN-Ø100 or AN-Ø120 into pre-drilled opening of an adequate size in the wall or the ceiling.
Remove front mask (A), releasing the mask holder (1) with the tip of the screwdriver until it is released, and
then pull the mask toward yourself.
The ventilator body (D) should be put into the opening on the wall or the ceiling. The ventilator frontal part (B) should
be positioned and fixed using the classical method with wall plugs and screws (2) or by fixing with a flange (4) on the
back side (in case of installation on window).
A
1
1
D
B
3
C
4
2
NOTE:
- The ventilator must be installed on the height over 2.3 m from floor level!
- Before removal of the ventilator front mask (A) always check whether the appliance is disconnected from power supply!
FIGURE 1. Ventilator components