To select, edit & save the
value / parameter
To decrement value and
scroll the parameter
Programming Parameter
Default
Option/Range
to decrement values / change the available opons.
to save the opon / value of the parameter.
Method of VA
Selection
Baud rate
Parity
Device ID
Energy selection
Starting voltage
Password
Starting Amps
Option : Arithmetic , Vector
harmonics, Vector
Option : 2400, 4800, 9600,
19200, 38400
Option : EVEn / odd / no
Range : 1-247
Option : Wh,VAh
Range: 10 to 40V
Range: 1000 -9999.
Range: 0.02 to 10% of FS
Press Down key connuously for 5 secs or unl display
shows Display starts to scroll parameters every 5 sec.
To disable Autoscrolling, Press any key, display shows and remains
in a parcular page.
True RMS measurement.
User configurable (Editable) password
Simultaneous sampling of Volts & Amps.
RS485 optional.
Inverse Current tripping.
Over current, Under and Over Voltage protection when it is running
on DG.
Programmable DG start time which avoids overloading the DG.
Intelligent controller trips exactly on the programmed settings.
Resetting the Trip by key press or through communication.
Programmable EB healthy selection (All phases/1Phase).
MCB reset (OFF & ON) option available for overload in DG for
M300 & M330 models.
Value Indication
To view the
parameters
Downwards and
Reset during trip
To view the
parameters
Upwards.
Communication
DG - Power
Trip
EB - Power
Kilo
DG high Voltage
DG low Voltage
DG over Amps
Range: 240 to 270V
Range: 165 to 210V
Range : 0 to 40A/50A/63A/80A/
100A/125A
Cycle 1 set time
Range : 6 to 150sec
Cycle 2 set time
Cycle 3 set time
Cycle 4 set time
No.of trip Cycle
DG Output
selection **
Range : 6 to 150sec
Range : 6 to 150sec
Range : 6 to 150sec
Range : 5 to 10
Options : 3phase, 1phase
Press Down to change the opons y(save) or n(not save).
Press Up to save.
and
to edit next parameter ll end of last parameter
display screen will prompt with display reads blinking.
to enter Setup mode Display shows 0000).
If Password is correct, eding is possible.
Enters into Setup mode and meter display's VA Selecon.
to view the setup parameter.
Press Up to view the parameter opon /value.
Again press Up key to select and edit parameter value /opon
Enter Password (default is 1000).
Blinking digit indicates eding of that digit.
DG delay time
Range : 1 to 30 sec
EB over Amps *
Range : 0.500 to 40A/50A/63A
/80A/100A/125A
3.4 Enabling and Disabling Auto Scrolling
Save
Yes/No
EB healthy
selection #
Options : ALL.P(all phase) ,
Any 1phase
Minus
XXX
* Not applicable for M100C without RS485 option.
** Not applicable for M100C & M330.
# Not Applicable for M100C.
For M330 DG selection factory set only.
Current rating:
M100C: 40A/50A/63A
M300: 40A/63A/80A/100A/125A
M330: 40A
PG/ACCL6K5/V4/0221
iACCL
M300
M330
M100C
support@elmeasure.com
Toll Free: 1800 120 5048
User Manual
www.elmeasure.com
Head office & Manufacturing Unit 1
Plot N0.: 47-P, KIADB Hardware Park,
Huvinayakanahalli, Bengaluru - 562 149,
Karnataka INDIA.
Manufacturing Unit 2
Goutham Garden, No.4, Veerapandi,
Coimbatore - 641019 Tamil Nadu, INDIA
Elmeasure India Private Limited
www.elmeasure.com
iACCL M 300
Question and Answer IconNeed help?

Do you have a question about the elmeasure iACCL M Series and is the answer not in the manual?

elmeasure iACCL M Series Specifications

General IconGeneral
Brandelmeasure
ModeliACCL M Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

Device Features

True RMS Measurement

Measures true RMS values for voltage and current.

User Configurable Password

Allows users to set a custom password for device access.

Simultaneous Sampling

Samples voltage and current simultaneously.

RS485 Communication

Optional communication interface for data exchange.

Inverse Current Tripping

Detects and trips on inverse current conditions.

Voltage Protection

Protects against over and under voltage during DG operation.

Programmable DG Start Time

Configurable delay for DG start to prevent overloading.

Intelligent Trip Control

Trips precisely based on programmed settings.

Trip Reset Functionality

Allows resetting trips via key press or communication.

EB Healthy Selection

Configurable selection for EB healthy state (All/1Phase).

MCB Reset Option

Option to reset MCB (OFF & ON) for DG overload.

Key & LED Indicators

Power Indicators

Indicates power status from EB and DG supplies.

Trip Status Indicator

Indicates when a trip condition has occurred.

Value Display

Displays parameter values and status.

Programming Buttons

Buttons for decrementing, incrementing, and saving parameters.

Programming Mode Operations

Programming Key Functions

Defines the function of Up/Down keys for programming.

Setup Procedure

Step-by-step guide to enter setup and modify parameters.

Display Navigation

Instructions for navigating through display parameters and options.

Programmable Parameters

Details adjustable parameters like voltage, current, time, and communication settings.

Auto Scrolling Control

How to activate and deactivate automatic scrolling of parameters.

Parameter Display Meanings

Parameter Codes

Explains the meaning of various display codes (LL, Ln, F, A, U, UA, PF, etc.).

Wiring Diagrams

EB & DG 3 Phase Wiring

Shows wiring connections for EB and DG 3-phase inputs.

EB & DG 1 Phase Wiring

Illustrates wiring for EB and DG 1-phase inputs.

EB 1 Phase & DG 1 Phase Wiring (M100 C)

Wiring diagram for M100C model with EB and DG 1-phase inputs.

Mechanical Specifications

Surface Mounting Dimensions

Provides outer dimensions for surface mounting of various models.

Important Information & Safety

Manufacturer Disclaimer

States manufacturer's non-liability for incorrect use or hazards.

Cautionary Notes

Highlights hazardous voltages and requires qualified personnel for installation.

Wiring Lugs

Advises on proper use of copper wire and lugs to prevent shorts.

Related product manuals