Type no.: 350HB002 Version: 1.3 Date: 13.04.2016 8-86
8.5.2 EloProg error codes
In the case of malfunctions is the eloProg system is able to transmit the error code to the eloProg
software corresponding to the error detected by the master 485EPB.
To read the code, proceed as follows:
Connect the Master 485EPB (indicating FAIL via LED) to the PC using the USB cable;
Launch the eloProg software , a window appears with the detected error code.
Tab. 8-4
lists all possible errors that can be detected and their solution.
Tab. 8-4 Possible errors
All other codes are related to internal faults or malfunctions. Faulty modules are to be re-
placed.
CODE FAIL RESOLUTION
19D
The two microcontrollers do not see the same hw/sw
configuration
Check correct insertion of 485EPB and expansion
module MSC-connectors.
Possibly replace the connectors
66D
2 or more of the same expansion modules with the same
node number
Check the connections of PINs 2 and 3 of the expansion
modules
68D Exceeded max. expansion modules number Disconnect the modules in excess (max. 14)
70D
One or more modules have detected a change in the node
number
Check the connections of PINs 2 and 3 of the expansion
modules
73D A slave module has detected an external error Check the error code on module for more information
96D ÷ 101D Errors related to memory 350EPS Replace 350EPS memory
137D
From a 485EPR04S00B 485EPR04S08B - EDM error on the
couple Relay1 and 2 used in Category 4
Check the connection of the external feedback contactors
147D
From 485EPR04S00B or 485EPR04S08B - EDM error on
the RELAY2 and 3 used in Category 4
Check the connection of the external feedback contactors
157D
From a form or 485EPR04S00B 485EPR04S08B -
EDM error on the RELAY3 and 4 used in Category 4
Check the connection of the external feedback contactors
131D
From a 485EPS2, 485EPS1 or 485EPS2N - detected
disconnection Proxi 1 or 2
Check the proxy connections
132D From a 485EPS2 - disconnection detected encoder 1 and 2 Check the connections of encoder
142D
From a 485EPS1 or 485EPS2 - disconnection encoder 1
detected.
Check the connections of Encoder1
144D
From a 485EPS2, 485EPS1 or 485EPS2N - disconnection
Proxi 1 detected
Check the proxy connections
152D From a 485EPS2 - disconnection encoder 2 detected Check the connections of Encoder2
154D
From a 485EPS2, 485EPS1 or 485EPS2N - disconnection
Proxi 2 detected
Check the connections of Proxy2
194D 197D
198D 199D
201D 202D
203D 205D
Errors with respect to the static output OSSD1
Check the connections with respect to the OSSD1
module which gave the error
208D 211D
212D 213D
215D 216D
217D 219D
Errors with respect to the static output OSSD2
Check the connections with respect to the OSSD2
module which gave the error
222D 225D
226D 227D
229D 230D
232D 233D
Errors with respect to the static output OSSD3
Check the connections with respect to the OSSD3
module which gave the error
236D 239D
240D 241D
243D 244D
245D 247D
Errors with respect to the static output OSSD4
Check the connections with respect to the OSSD4
module which gave the error