764 ENVIRONMENTAL MONITOR
USER MANUAL
LITTLEMORE SCIENTIFIC ENGINEERING (ELSEC)
Gutchpool Farm
Gillingham
Dorset
UK
Tel: (+44) (0)1747 835550
Fax: (+44) (0)1747 835552
Email: elsec@elsec.co.uk
764.DOC V3.702
Question and Answer IconNeed help?

Do you have a question about the ELSEC 764 and is the answer not in the manual?

Summary

Introduction to the 764 Environmental Monitor

Basic Operation of the 764 Monitor

Using the Set Button

The blue Set button accesses advanced functions and unit changes for the device.

Understanding Measurement Units

Ultra-Violet (UV) Measurement

Details UV measurement units like µW/lumen and mW/M², with recommended museum levels.

Visible Light Measurement

Covers visible light readings in Lux or Foot-candles and suggested museum light levels.

Temperature Measurement

Explains temperature measurements in Centigrade or Fahrenheit.

Humidity Measurement

Defines humidity as %RH and discusses dewpoint measurement.

Maximum and Minimum Readings

Display Settings and Options

Adjusting Display Contrast

Guide to adjusting the display's contrast level.

Backlight Operation

Options for controlling the display backlight based on light conditions.

Data Logging Functionality

Wrap Data Configuration

Sets data logging to overwrite old data or stop when memory is full.

Checking Data Logging Status

View current data logging status, saved data amount, and start time.

Starting Data Logging

Procedure to initiate data logging and select logging intervals.

Stopping Data Logging

Instructions on how to stop data logging and preserve recorded data.

Re-starting Data Logging

Steps to resume logging after power interruptions or battery changes.

Logger to PC Communications

Details on establishing PC connection for data download and logger configuration.

Installing the Software

Viewing Results with RView Software

Clock Settings

Setting the Time

Step-by-step guide to setting the device's internal clock time.

Setting the Date

Procedure for setting the current date on the device.

Changing Date Format

Explains how to change the date display format (DMY/MDY).

Hiding the Clock Display

Method to hide or unhide the clock display on the device screen.

Maintenance Procedures

Battery Replacement

Information on replacing the device batteries and recommended types.

Mains Power Supply Connection

Details on connecting an optional external mains power supply.

Checking Software Version

How to check the internal software version of the device.

Calibration of the Monitor

Humidity Calibration

Procedure for checking and calibrating the humidity sensor.

Using the Calibration Kit

Description of the humidity calibration kit components and usage.

Temperature Calibration Adjustment

Procedure for checking and adjusting the temperature sensor offset.

UV and Visible Light Calibration Notes

Service and Support Information

Technical Specifications

ELSEC 764 Specifications

General IconGeneral
Accuracy±(1% of reading + 0.5% of range) (DC); ±(2% of reading + 1% of range) (AC)
Dimensions160 x 80 x 36 mm
Weight270 g
DisplayLCD
Power SupplyBattery
Resolution0.1 dB