Lock Time
Whentheauxiliaryrelayisprogrammedasalockoutputtherelayisactivatedforasettimeonthe
openingandclosingcycle.Thefactorydefaultlocktimeis2seconds.
Tochangethedefaultlocktimefollowthesesteps:
1. SetmodeswitchtoProgramMode1
2. Setdipswitch6and7“ON”
3. PressButtonAfortherequireddurationofthelocktime
4. ReleaseButtonA
5. Buzzerwillbeeptoindicatelocktimehasbeenchanged
6. Switchoffalldipswitches
7. SetmodeswitchtoRunmode
Brake
Whenenabledthisfeatureappliesbraketothegate/doorwhenitstops.Idealifthegate/doorisinstalled
inaslopingplane.Thefactorydefaultis“OFF”.
Toenablebrakefollowthesesteps:
1. SetmodeswitchtoProgramMode1
2. Setdipswitch5and7“ON”
3. Setdipswitch1to4and6,8to“OFF”
4. Pressbutton“A”toenablebrake
orpressbutton“C”todisablebrake
5. Switchoffalldipswitches
6. SetmodeswitchtoRunmode
Overrun Time
Theoverruntimeisextratimeaddedtothelearnttraveltime.Addingoverruntimecancompensatefor
windormechanicalloading.Thefactorydefaultis10sec.
Tochangeoverruntimefollowthesesteps:
1. SetmodeswitchtoProgramMode1
2. Setdipswitch5“ON”
3. Setdipswitch1to4and6,7,8to“OFF”
3. Pressbutton“A”for30seconds,“C”for10secondsor“E”for2seconds
4. Switchoffalldipswitches
5. SetmodeswitchtoRunmode