42 User Manual THEIA HE-t String Inverters 357115.013, Issue 1.0, 2011 March
5a. Country Settings
Enter – The question “Change country
settings?” appears on the screen
Left or Right – Select CANCEL or OK
Enter – Confirm
5b. Country Settings
Enter - Call up the list of countries
Up or Down - Select the country of the actual
installation site
EnterConfirm
NOTICE!
Change Country Settings: An installation timer ensures that the country settings can be
changed within the initial 5 hours of feeding power into the grid after installation. Thereafter
it is only accessible using the Installer password, which may only be obtained for installers
and grid operators by contacting Eltek Valere.
CAUTION: Ensure correct country settings!
The selected country must match the actual installation site; otherwise the inverter
may not operate or be compliant to relevant local and national regulations due to
incorrect limit values.
6. Screen Timeout
Enter – Call up the digits
Default: Screen backlight OFF after 60 sec
NOTICE!
The smallest value to be set is 30 sec, and the highest is 99 sec.
Setting the value 0 disables the screen timeout and leaves the screen backlight ON.