User Manual THEIA HE-t String Inverters 357115.013
,
Issue 1.0, 2011 April
45
11. Owner Password
Enter – Call up the digits
Default: 0003.
Change the password to 4 optional digits
NOTICE!
This password is not transmitted to other
inverters on the CAN bus
NOTICE!
With several inverters connected it must be checked that the installation is carried out on all
the slave inverters.
• Look at the displayed menu and the LEDs: It is not carried out correctly if the installation
menu is still displayed and/or the yellow and red LEDs are lit.
• Check that the connection of the CAN cables are correct, that the DC switches are ON and
that the power is >7 W
DC
.
• If the Start Up phase is correctly carried out the inverters are ready to use. They are fully
automatic during normal operation, and no manual control is necessary for feeding power
into the grid.