50 User Manual THEIA HE-t String Inverters 357115.013, Issue 1.0, 2011 March
Access Levels and Passwords
There are three access levels to the different submenus:
Guest
Read all values.
Owner
Read all values and set all values except grid settings and other installer
related values.
Default Owner password is 0003, but can be changed in Setup>General
Setup>Password.
If the password is lost or forgotten, contact Eltek Valere.
Installer
Read and set all values. The Installer password is based on the serial
number; and can only be obtained by contacting Eltek Valere.
NOTICE!
Any change of setting needs a password. Once the password has been entered, modifications
must be done within 1 minute before the access resets to Guest level.
6.2.1. Home
The Home screen is the default screen, which
is always shown if no buttons are touched for
1 minute.
Values of PV (DC) and feed-in (AC) current,
voltage and power are shown numerically.
The instantaneous output power is shown as
a bar graph.
Up or Down – Navigate in the screen.
Left or Right – Observe the daily, monthly
and total yearly values of energy harvest
[Wh/kWh], peak power [Wp], earning
value and avoided CO
2
emission [kg].
photovoltaikforum.com