3.7 Connecting socket for function and fault signals
The 5-pin connecting plug (Fig. 5) is only provided in units equipped with
function and pollution monitoring. Depending on requirements, the follow-
ing signals can be picked up at this plug:
Output voltage active: contact 1, 2, 5 (contact 1 and 5 closed)
fault/pollution: contact 3, 4, 5 (contact 3 and 5 closed).
Cables prefabricated at one end are available for connection to this plug
(see accessories).
Wire colours:
1 = white, 2 = brown, 3 = green, 4 = yellow, 5 = grey.
Fig. 5:
Assignment of the
plug for function
and fault signals
(contacts at rest)
Z00009y