1
Monitoring Tools
1-11
Introducing Fabric Watch
3. Index number for the element involved.
The index number consists of three digits and corresponds to
where the element appears in respect to others in a series. For
instance, if the element in question is the third temperature sensor
on a switch, its number would be 003.
Numbering for all port and SFP classes begin with index number 000 (as
per the Fabric OS port numbering convention), but environment class
index numbers begin with 001. Therefore, the first element in a series of
ports will be 000, but the first element in a series of thermometers will be
001. For the fabric class, the index number is always 000. The threshold
name is case sensitive.
Example fopportState003 represents a state threshold of the fourth port
(which contains an optical SFP).
E_Port down ED
Fabric login FL
Fabric reconfigure FR
SFP state change SS
Segmentation change SC
Zoning change ZC
Name server login NL
Name server request NR
Invalid CRCs CRC
TX performance TX
RX performance RX
Filter frame counter PT
Table 1-3 Area Name Abbreviations (
continued
)
Area Abbreviation