Configuring alert settings
You can configure storage system alert settings for email notifications and SNMP
traps from the storage system.
Configure alert settings for email notifications
Using Unisphere:
Procedure
1. Select Settings > Alerts > Email and SMTP.
2. In the Specify Email Alerts and SMTP Configuration section under Send
email Alerts to the following email list, configure the email addresses to
which to send alert notifications.
3. Under Severity level of alerts to send:, configure the severity level at which
alert email messages are generated to one of the following:
l
Critical
l
Error and Above
l
Warning and Above
l
Notice and Above
l
Information and Above
For the storage system alert email mechanism to work, a target SMTP server
must be configured for the storage system.
4. Under Specify SMTP network settings:, configure the target SMTP server.
Configure alert settings for SNMP traps
Using Unisphere:
Procedure
1. Select Settings > Alerts > SNMP.
2. In the Manage SNMP Alerts section under Send alerts through SNMP traps
to these destinations:, configure the following information for the SNMP trap
destinations:
l
Network name or IP address
l
Authentication protocol to use
l
Privacy protocol to use
3. Under Severity level of alerts to send:, configure the severity level at which
SNMP traps are generated to one of the following:
l
Critical
l
Error and above
Security Alert Settings
Configuring alert settings 63