Disk-array enclosure
VNX5500 Hardware Information Guide 79
6-Gb/s SAS port LED and port direction (input or output)
Figure 68 shows the LCC 6-Gb/s SAS port LED—a bi-color (blue/green) LED next to the
connector, either left or right—that indicates the link/activity of the SAS port. Figure 68
also shows a double circle (or dot) symbol
(for input) or a double diamond symbol
(for output).
Note: Looking from the rear of the DAE, LCC B is located on the top and LCC A is located on
the bottom (Figure 68).
Figure 68 6-Gb/s SAS port LEDs
Table 43 describes the 3U, DAE LCC 6-Gb/s SAS port LEDs.
A11 Rx 3+ B11 Tx 3+
A12 Rx 3- B12 Tx 3-
A13 GND B13 GND
Table 42 6-Gb/s SAS port connector pinout (continued)
Pin Signal Pin Signal
3U, DAE LCC A 6-Gb/s SAS ports
3U, DAE LCC B 6-Gb/s SAS ports
VNX-000101
X4
6Gb SAS
X4
6Gb SAS
Table 43 6-Gb/s SAS port LEDs
LED Color State Description
Link/activity Blue On All lanes are running at 6 GB/s
Green On One or more lanes are not running at full speed or
disconnected
Alternating
Blue/Green
Blinking Port is being marked by the host
—OffNot connected