38 VNX5700 Hardware Information Guide
System component description
Figure 28 Data Mover management module
Data Mover management module Ethernet (RJ-45) ports
The Block and File (Unified) VNX5700 platform Data Mover management module comes
with three integrated dual-port Ethernet ports (labeled 0, 1, and 2) on the rear of the
management module. These ports provide an interface for connecting to 10-, 100-, or
1000-Mb/s networks providing full-duplex (FDX) capability, which enables simultaneous
transmission and reception of data.
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to
telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports
contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution
when connecting cables.
To access the Ethernet ports, connect a Category 3, 4, 5, 5E, or 6 unshielded twisted-pair
(UTP) cable to the RJ-45 connector on the back of the Data Mover management module
(Table 19 on page 42).
Since the Control Station and the Data Mover management module have the same type of
RJ-45 ports, the “Control Station Ethernet (RJ-45) ports” on page 42 provides more
information about the Data Mover management module ports.
1 Power/fault LED 5 DB-9 serial console socket connector
2 Data Mover management module push
button latch handle
6 RJ-45 Ethernet port (labeled 0)
3 RJ-45 Ethernet port (labeled 1) 7 RJ-45 Ethernet port (labeled 2)
4 Data Mover enclosure ID numeric display
2
0
1
#
1
2
3
4
5
6
7
CNS-001754