OPERATING INSTRUCTIONS FOR
“JA SERIES” / “JA SERIES PRO” CONTROLLERS
This manual contains safety information that if ignored can
endanger life or result in serious injury. They are indicated
by this icon.
Keep the controller protected from sun and water.
Avoid water splashes.
Read Carefully !
ENGLISH Version
R19-07-19
Question and Answer IconNeed help?

Do you have a question about the Emec JAPH PRO Series and is the answer not in the manual?

Emec JAPH PRO Series Specifications

General IconGeneral
BrandEmec
ModelJAPH PRO Series
CategoryController
LanguageEnglish

Summary

JA Series Controller Operating Instructions

Safety Warnings and Precautions

Manual contains safety info indicated by icon. Keep controller protected from sun and water.

General Safety Guidelines

Emergency, Installation, and Liability

Emergency shutdown, local regulations, manufacturer liability, and accessibility for operation/servicing.

Pump, Feeder, and Chemical Safety

Safety for pumps, feeders, chemical handling, protective clothing, and reading datasheets.

Mainboard Connections (JACD;JACD PRO)

Output and Terminal Connections

Describes connections for Setpoint 1, Setpoint 2, Alarm, Standby, and Opto-coupled outputs.

Sensor and Communication Interfaces

Details connections for proximity sensors, RS485, Conductivity probe, PT100 probe, and mA output.

Extended Connections for Multiple Series

Probe and Sensor Input Wiring

Details connections for Inductivity probe, SCL probe, ECL6 probe, PT100 probe, and mA output.

Main Screen Interface

Quick Status Check Functionality

Password Management and Security

Setting Administrator Password

How to set a new administrator password with four numbers for accessing the main menu.

Main Menu Navigation Guide

Key Main Menu Sections Overview

Lists main menu options like SETTINGS, FLOW, GENERAL OPTIONS, RESET INSTRUMENT, OUT MA, STAND-BY.

Settings Configuration Options

Measure Settings for JA CD;CDIND

How to select K factor and automatic range for conductivity measurement on JA CD/CDIND series.

ON;OFF Mode Operation Details

Proportional Mode Operation Details

PID Mode Operation (PRO Models)

Understanding PID Control Principles

Explains PID controller basics: proportional, integral, derivative terms for process control.

Configuring PID Parameters

Details setting Time Integrative, Time Derivative, and Mode for PID control in PRO models.

Calibration Procedures (JA CD Series)

Conductivity Calibration Steps

Steps for calibrating conductivity using a SLOPE value and buffer solution.

Temperature Calibration Steps

Procedure for calibrating temperature using a professional thermometer and PT100 probe.

Calibration Procedures (JA PH Series)

Full pH Calibration Process

Involves two points (Offset/Slope) using pH 4.00 and 7.00 buffer solutions for accurate pH measurement.

Calibration Procedures (JA RH Series)

ORP Calibration Methods

ORP calibration uses one point (P1), with options for FAST (1 buffer) or FULL (2 buffers) calibration.

Temperature Compensation for Conductivity

Calibration Procedures (Other Series)

Modbus Communication Protocol

Output and Standby Configuration

Technical Specifications and Ratings

Related product manuals