Read Carefully !
ENGLISH Version
R12-01-18
OPERATING INSTRUCTIONS F O R
“MTOWER PLUS” INSTRUMENT
This manual contains safety information that if ignored
can endanger life or result in serious injury. They are
indicated by this icon.
Keep the instrument protected from sun and water.
Avoid water splashes.
CD/PH/RH Version

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emec MTOWER PLUS Series and is the answer not in the manual?

Emec MTOWER PLUS Series Specifications

General IconGeneral
CategoryController
SeriesMTOWER PLUS
Operating Temperature-10°C to +50°C
Weight0.5 kg
ProtectionOverload, Short Circuit

Summary

General Safety Guidelines

Safety Warnings - Danger

In emergencies, switch off the instrument immediately and disconnect the power supply.

Safety Warnings - Caution

Ensure instrument accessibility for operation and servicing; avoid obstructions.

Mainboard Connections

Power Connections

Details on fuses, main power supply (90VAC to 265VAC), and earth connection.

I;O Connections

Overview of input/output connections for probes, outputs, and alarm signals.

MTOWER PLUS Basic Treatments

MTOWER PLUS Basic Settings

Passcode Setup

Procedure for setting and changing the passcode for accessing setup and probe menus.

Time & Date Setup

Clock Menu Configuration

Steps to access and set the instrument's date and time.

Units Setup

International Unit Standards

Guide to configuring units between EUROPE IS (Metric) and USA (Imperial) standards.

MTOWER PLUS Standard Settings

Conductivity Calibration (uS)

Procedure for calibrating the conductivity probe using P1 and P2 points.

TE & CA Settings

Temperature Compensation (TE)

Manual and automatic temperature compensation for conductivity measurements.

Automatic Compensation (CA)

Enabling or disabling automatic temperature compensation for conductivity.

Calibration pH Menu

pH Calibration - 1 st Point

Procedure for the first calibration point of pH using buffer solution.

Calibration pH Menu - 2 nd Point

pH Calibration - 2 nd Point

Procedure for the second calibration point of pH using buffer solution.

Calibration pH Menu - TE & CA

pH TE & CA Settings

Adjusting temperature compensation for pH measurements.

Calibration mV Menu

ORP Calibration Overview

Introduction to the ORP calibration procedure using a single calibration point.

Calibration mV Menu - P1

ORP Calibration - 1 st Point (P1)

Detailed steps for ORP calibration using a buffer solution or DPD1 method.

Calibration Temp Menu

Temperature Probe Calibration

Procedure for calibrating the temperature probe using an external thermometer.

Inhibitor Menu

Inhibitor Feeding Modes

Configuration of 5 feeding modes for inhibitor: Feed & Bleed, % Bleed, % Time, Water Meter.

Biocide 1 and Biocide 2 Menu

Bleed Menu

Bleed Control Parameters

Configuring Setpoint, Dead Band, Time Limit, and Manual Bleed for bleed valve operation.

Set-Point mV Menu Modes

Set-Point ORP PWM Mode

Set-Point ORP - Proportional P1

Set-Point pH Menu Modes

Set-Point pH (on;off) Mode ACID

Set-Point pH (PWM)

Set-Point pH (Proportional)

MTOWER PLUS Advanced Settings

Alarm Menu

Alarm Configuration and Outputs

Enabling/disabling system alarms and configuring related outputs like conductivity, pH, ORP, and flow.

Manual Menu

Addendum Water Meter on mA module