Ceiling Fan Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch
start. blown. circuit fuses or circuit breakers.
WARNING: Make sure
main power is turned off.
2. Loose power line 2. Check line power connections
connections to the fan. to fan.
3. Fan/Light Remote Control is OFF. 3. Turn ON Fan/Light Remote Control.
2. Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before
noisy. operating.
2. Screws securing fan blades 2. Check to make sure the screws
to motor are loose. which attach the blades to the
motor are tight.
WARNING: Make sure main
power is turned off.
3. Loose screws in motor housing. 3. Check to make sure all screws
in motor housing are snug
(not over-tight)
3. Fan wobbles 1. Setscrews in motor coupling are 1. Raise coupling cover and tighten
excessively. not tightened securely. setscrews securely.
2. Setscrew in the hanger ball/ 2. Tighten the setscrew in the
downrod assembly is loose. hanger ball/downrod assembly.
3. Screws securing fan blades 3. Check to be sure screws which
to motor are loose. attach the fan blade to the
motor are tight.
4. Fan blades are not seated 4. Check to be sure that the
properly. screws securing the fan
blades seat firmly.
5. Hanger bracket and/or ceiling 5. Tighten the hanger bracket
outlet box is not securely screws to the outlet box, and/or
fastened. secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side
by-side) blade pair can
redistribute the weight and result
in smoother operation.
Or use supplied balancing kit to
balance blades.
4. Both lamps will 1. Loose electrical connectors. 1. Shut off the branch circuit
not illuminate. electricity at the fuse box or
breaker panel and check the
receiver electrical connectors
for proper installation.
2. Remote control battery is weak. 2. Replace the AAA remote
batteries.
3. The lamps are burnt out. 3. Turn the electricity off and
replace the lamps with new
50W max. lamps.
4. Lamps turn on and then turn off. 4. The built in circuit breaker is
tripping, check that the lamps
are each 50W maximum.
CAUTION: Turn the lights off
before touching halogen lamps,
they are very hot and can burn
your fingers.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR
CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!