144
Epsilon Eb and EN Drives Reference Manual
Many position controllers define acceleration in units per sec
2
. The formulas above use ms/
kRPM. Make sure you make this conversion when entering the information into the formula.
Conversion Formula:
Where:
MPK = accel ramp in ms/kRPM
RPSS = accel ramp in revolutions per second
2
Motor Drive Vm
Percent Continuous/volt
Scaled Torque Command
Output (default))
RPM /volt Scaled Velocity
Command Output (default))
NT-320
EN-204
4.30 30 600
MG-205 4.77 30 600
MG-208 5.11 30 600
MG-316 3.17 30 600
NT-320
EN-208
5.16 30 600
NT-330 6.87 30 600
NT-345 6.72 30 600
NT-355 5.97 30 600
MG-316 3.17 30 600
MG-340 3.14 30 600
MG-455 2.44 30 600
NT-345
EN-214
6.72 30 600
NT-355 5.97 30 600
MG-455 2.44 30 600
MG-490 1.85 30 600
MG-4120 1.69 30 600
NT-207
Eb-202
7.27 30 600
NT-212 5.37 30 600
MG-205 4.77 30 600
MG-208 3.63 30 600
NT-207
Eb-203
7.27 30 600
NT-212 7.22 30 600
MG-205 4.77 30 600
MG-208 4.63 30 600
MG-316 2.67 30 600
60) (RPSS
10
MPK
6
·
=
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Emerson Control Techniques EN Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Control Techniques EN Series and is the answer not in the manual?

Emerson Control Techniques EN Series Specifications

General IconGeneral
BrandEmerson
ModelControl Techniques EN Series
CategoryDC Drives
LanguageEnglish

Related product manuals