EasyManua.ls Logo

Emerson Control Techniques Epsilon Eb Series - Page 107

Emerson Control Techniques Epsilon Eb Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88
Epsilon Eb and EN Drives Reference Manual
the required KVA rating are high transformer ambient temperatures (>40° C or >104° F) and
drive operation near the maximum speeds.
Transformer output voltage drop may become a limiting factor at motor speeds and loads near
maximum ratings. Typically, higher KVA transformers have lower voltage drop due to lower
impedance.
Drive/Motor Combination Suggested KVA Rating
EN-204/NT-320 3.0
EN-204/MG-205 0.8
EN-204/MG-208 1.5
EN-204/MG-316 2.3
EN-208/NT-320 3.0
EN-208/NT-330 3.9
EN-208/NT-345 4.3
EN-208/NT-355 4.9
EN-208/MG-316 2.3
EN-208/MG-340 3.9
EN-208/MG-455 4.9
EN-214/NT-345 4.3
EN-214/NT-355 4.3
EN-214/MG-455 4.3
EN-214/MG-490 6.0
EN-214/MG-4120 6.5
Eb-202/NT-207 1.0
Eb-202/NT-212 1.2
Eb-203/NT-207 1.0
Eb-203/NT-212 1.7
Eb-203/MG-316 2.3
Eb-205/NT-212 1.7
Eb-205/NT-320 3.0
Eb-205/NT-330 3.0
Eb-205/NT-345 3.0
Eb-205/MG-340 3.0
Eb-205/MG-316 2.3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Related product manuals