TI_Stream_NGCS_04_E_Rev04 1/2
Date of last update: Mar-21
Ref: TI_Stream_NGCS_04_E_Rev04
Application Engineering Europe
COPELAND COMPRESSOR ELECTRONICS
FOR COPELAND STREAM COMPRESSORS QUICK INSTALLATION GUIDE
The Copeland Compressor Electronics module (previously Next Generation CoreSense) is located in the Stream
compressor terminal box. It is prewired to the oil pressure sensor (for compressors with an oil pump), the motor
thermistor chain (PTC), the discharge temperature sensor and the current sensor.
Figure 1: Terminal box Figure 2: Internal view of terminal box
1. Unscrew the 4 screws located in the corners of the compressor terminal box cover and lift off the terminal box
cover.
2. Open the cover of the Copeland Compressor Electronics module to access the terminals.
Figure 3: Copeland Compressor Electronics module cover open Figure 4: Current sensor
3. Supply 115 V or 230 V power (N and L1) to the module on extreme left terminals 1 and 2 (both polarities are
possible).
4. Position the jumpers according to starting method and motor type. The jumper position is given on the compressor
wiring diagram.
5. Connect the power supply to the terminal plate.
6. Caution! For part-winding, the power leads from the same phase should go through the current sensor in the
same direction.

Other manuals for Emerson Copeland 4MTL-05

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Copeland 4MTL-05 and is the answer not in the manual?

Emerson Copeland 4MTL-05 Specifications

General IconGeneral
BrandEmerson
ModelCopeland 4MTL-05
CategoryAir Compressor
LanguageEnglish

Related product manuals