13
September 2018
SIL Safety Manual
DOC.SILM.EF.EN Rev. 1
Periodic Test and Maintenance Requirements
NOTE:
If the test is automatic, then the Test Coverage can also considered as DC.
If the test is manual, then the Test Coverage cannot be considered as DC.
Parameters to be measured:
The following parameters have to be measured for an effective Partial Stroke Test:
Angular position of the shaft;
Time necessary to reach to nal position;
Output torque (as indirect measure, by means of the of pressure measurement in the
cylinder chamber)
NOTE:
Not all parameters are needed, but the following combinations can be used:
1. Measurement of angular position as function of time
(pressure measurement is optional).
2. Measurement of cylinder chamber pressure as function of time.
3. Verication of nal position achievement in the established maximum time.
The parameters to be measured depend upon the partial stroke test system available.
Instruments / equipment to be used for the test:
The Partial Stroke Test can be executed in the following way:
1. Using commercial Partial stroke testing device, measuring/verifying:
a. Measurement of angular position as function of time.
b. Measurement of cylinder chamber pressure as function of time (optional).
c. Verication of nal position achievement in the established maximum time.
2. By means of Logic Solver, measuring/verifying:
a. Measurement of angular position as function of time.
b. Measurement of cylinder chamber pressure as function of time (optional).
c. Verication of nal position achievement in the established maximum time.